Configuration
By increasing this value, the precision
is increased but the speed of variation
is reduced.
24
Maximum percentage variation of
increase/decrease of the flow rate:
10, 20, 30, 40, 50% of the value set on
the monitor.
25
Adjustment response:
Allows the response time of the
automatic adjustment to be changed.
-
Auto: automatic, the system
automatically varies the
adjustment time according to the
current conditions.
-
Low: slow adjustment response
time. In this mode, the
adjustment is more accurate but
slower to respond to changes.
-
Average: average adjustment
response time.
-
High: long adjustment response
time. In this mode the system is
faster.
-
Customized: parameter reserved
for the manufacturer. Do not use
this setup unless expressly
specified.
26
Adjustment sensor
Selects the sensor used for adjustment.
-
Flowmeter: the system uses the
flowmeter to adjust the dose
(l/ha)
-
Pressure: the system uses the
pressure sensor to adjust the
dose (l/ha)
-
Both: the system uses the
flowmeter or pressure sensor to
adjust the dose (l/ha). When the
flow rate (l/min) falls below the
GeoSystem RevA6
25
-