Configuration
calibration....in this example: vehicle
1).
4
Flowmeter calibration:
This specifies how many pulses arrive
at the flowmeter per unit of liquid
sprayed.
1-5000 pulses/liter (Metric) or
pulses/USG (gallon) (US).
The value is indicated on the plate
attached to the housing or by the
flowmeter manufacturer.
5
Minimum flow alarm threshold:
If the flow falls below this threshold, a
message will appear on the display. 0-
10000 l/min (Metric) or USGpm
(gal/min) (US)
6
Maximum flow alarm threshold:
If the flow goes above this threshold, a
message will appear on the display. 0-
10000 l/min (Metric) or USGpm
(gal/min) (US) (l/min).
7
Speed sensor calibration:
Indicates the wheel constant = distance
traveled (cm or inches) / pulse.
NB. There is a procedure for the
automatic calculation of the constant
over a distance of 100 meters.
8
Pressure sensor calibration:
0-200 full scale value (bar or psi).
9
Tank capacity:
0-10000 liters (Metric) or USG (gal)
(US).
GeoSystem RevA6