Calibration Procedure - Tecomec GEOline GEOSYsTEM 240 Instruction Manual

Table of Contents

Advertisement

Configuration
13.2

CALIBRATION PROCEDURE

These procedures must be carried out when the treatment is not active (in manual mode
and with all the switches in the OFF position).
- NOZZLE CALIBRATION:
This allows the characteristics of the nozzle type used to be defined (liter/minute) as a
function of the pressure (bar). It is possible to choose from a set of pre-configured (ISO
standard) types or to define new ones.
- TANK LEVEL CALIBRATION:
This sets the calibration points related to the tank level sensor.
- SPEED SENSOR CALIBRATION:
This calculates the proximity speed sensor calibration constant based on a known
distance to travel (100 m in the EU and 300 feet in the US).
1
Turn on the monitor by pressing
.
2
Keep pressing the
and
time.
Scroll through the 3 calibration items
using the
3
NOZZLE CALIBRATION (max 8).
4
Press the
nozzle configuration.
5
Press the
5 pairs of calibration values (Set 1-5)
related to the nozzle.
46
-
keys at the same
and
keys.
key to enter the
key again to set up to
GeoSystem RevA6