Configuration
13.2
CALIBRATION PROCEDURE
These procedures must be carried out when the treatment is not active (in manual mode
and with all the switches in the OFF position).
- NOZZLE CALIBRATION:
This allows the characteristics of the nozzle type used to be defined (liter/minute) as a
function of the pressure (bar). It is possible to choose from a set of pre-configured (ISO
standard) types or to define new ones.
- TANK LEVEL CALIBRATION:
This sets the calibration points related to the tank level sensor.
- SPEED SENSOR CALIBRATION:
This calculates the proximity speed sensor calibration constant based on a known
distance to travel (100 m in the EU and 300 feet in the US).
1
Turn on the monitor by pressing
.
2
Keep pressing the
and
time.
Scroll through the 3 calibration items
using the
3
NOZZLE CALIBRATION (max 8).
4
Press the
nozzle configuration.
5
Press the
5 pairs of calibration values (Set 1-5)
related to the nozzle.
46
-
keys at the same
and
keys.
key to enter the
key again to set up to
GeoSystem RevA6