16 ALARMS
16.1 WARNING AND ALARMS
There are warnings and alarms to indicate specific operating faults.
When an alarm goes off, a buzzer sound will be heard.
Press
key to disable the buzzer.
An active alarm is indicated by the
symbol to the right of the first line of the
display.

16.2 LIST OF POSSIBLE ALARMS

1. Flow adjustment alarm:
The monitor must reach a flow set point
value (l/ha); if it does not reach this value,
the alarm will go off after one minute.
2. Empty tank alarm:
This alarm is activated when the minimum
level of liquid in the tank is reached, as set
with the parameter: Minimum tank level
alarm threshold
3. Minimum flow alarm:
The amount of liquid sprayed (l/min) is
lower than the parameter: Minimum flow
alarm threshold
4. Maximum flow alarm:
The amount of liquid sprayed (l/min) is
higher than the parameter: Maximum
flow alarm threshold
5. Low battery level alarm:
The battery level is lower than 9.0 Volts
and