Configuration
18
Sensitivity to change in speed:
This changes the response time to the
adjustment in flow rate as a function of
the speed, from 1 (fast) to 5 (slow).
By increasing this value, the precision
is increased but the speed variation is
reduced.
19
Adjustment mode:
It is possible to change the mode of
automatic spraying adjustment:
Constant pressure or Constant volume.
For more information see section 13.6
20
Maximum percentage variation of
increase/decrease of the flow rate:
10, 20, 30, 40, 50% of the value set on
the monitor.
21
Adjustment response:
Allows the response time of the
automatic adjustment to be changed.
-
Auto: automatic, the system
automatically varies the
adjustment time according to the
current conditions.
-
Low: slow adjustment response
time. In this mode, the
adjustment is more accurate but
slower to respond to changes.
-
Average: average adjustment
response time.
-
High: long adjustment response
time. In this mode the system is
faster.
-
Customized: parameter reserved
for the manufacturer. Do not use
this setup unless expressly
specified.
22
Adjustment sensor
Selects the sensor defined for used for
adjustment.
-
Flowmeter: the system uses a
flowmeter sensor to adjust the
dose (l/ha)
-
Pressure: the system uses a
pressure sensor to adjust the
dose (l/ha)
GeoSystem RevA6