7-4

SNMP Trap Settings Display

l SNMP Trap
Setting
SNMP trap
*2
Port No.
*1.
If you specify to use the SNMP trap, you also have to set Trap 1 and Trap 2 as described below.
*2.
The following ports are used by the system and cannot be set by the user: 25, 53, 68, 110, 2222, 2223,
2224, 9600, and 44818.
Additional Information
Refer to 11-1-1 Overview on page 11-2 for details on the SNMP trap.
l Trap 1
If the Use Option is selected for SNMP trap, you need to make the following settings.
Setting
Specifying method
IP address
NX-series EtherNet/IP Unit User's Manual (W627)
7 Sysmac Studio Settings for the EtherNet/IP Port
Description
Specify whether to use the SNMP trap (network error detec-
*1
tion).
If the Do not use Option is selected for SNMP trap, SNMP traps
are not sent to the SNMP manager
Set the port number to use to connect to the SNMP server.
It is normally not necessary to change this setting.
Description
Set the specifying method for the SNMP manager destination for
SNMP traps.
IP address
Host name
Set the IP address of the SNMP manager.
(Set this setting if the Specifying method in the Trap 1 settings
is set to the IP address Option.)
Default
Do not use