To apply the same change to other connections, select the Apply the change to other
connections Check Box.
4
Click the OK Button.
Registering the Network Variable for the Target Device
1
Assign the network variable to the tag used for the EtherNet/IP connection for Controller 2 (tar-
get device).
This network variable stores data to send to Controller 1 (originator device).
Set the Network Publish attribute to Input or Output in the Global Variable Table for the varia-
ble so that the variable serves as a network variable, i.e., the variable can be used for the
EtherNet/IP connections. In this example, set the network variable for Controller 1 as shown
below.
• Name: Net_Out1
• Data type: WORD
• Network Publish attribute: Output
Registering the Tag and Tag Set for the Target Device
Set the tag and tag set for the target device.
1
Select EtherNet/IP Connection Settings from the Tools Menu.
The EtherNet/IP Device List Tab Page is displayed.
2
Right-click NX-EIP201, the NX-series EtherNet/IP Unit connected to the Controller 2 (originator
device in this example), and select Edit from the menu.
The EtherNet/IP Connection Settings Tab Page is displayed.
NX-series EtherNet/IP Unit User's Manual (W627)
Appendices
A
A-25