Omron NX Series User Manual page 268

Machine automation controller
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

10 CIP Message Communications
Attribute
Parameter name
ID
HC Media Counters
*1
0D hex
HCStatsAlignmentEr-
rors
HCStatsFCSErrors
HCStatsInternalMac-
TransmitErrors
HCStatsFrameToo-
Longs
HCStatsInternalMa-
cReceiveErrors
HCStatsMacSymbolEr-
rors
*1.
A CPU Unit with unit version 1.13 or later is required to use this attribute.
1. Interface Flag Details
Bit
Name
0
LinkStatus
1
Half/FullDuplex
2 to 4
Negotiation Status
5
Manual Setting Requires
Speed
6
Local Hardware Fault
10-40
Description
Media counters for the com-
munications port.
The number of frames re-
ceived that were not octets in
length. This counter is the 64-
bit edition of Alignment Er-
rors.
The number of frames re-
ceived that did not pass the
FCS check. This counter is
the 64-bit edition of FCS Er-
rors.
The number of frames that
failed to be sent due to an in-
ternal MAC sublayer trans-
mission error. This counter is
the 64-bit edition of MAC
Transmit Errors.
The number of frames re-
ceived that exceeded the
maximum allowed frame size.
This counter is the 64-bit edi-
tion of Frame Too Long.
The number of frames that
could not be received through
the interface due to an inter-
nal MAC sublayer reception
error. This counter is the 64-
bit edition of MAC Receive
Errors.
The number of frames that
could not be received through
the interface due to an inter-
nal MAC sublayer rsymbol er-
ror.
FALSE: The link is down. TRUE: The link is up.
FALSE: Half duplex TRUE: Full duplex
00 hex: Auto-negotiation is in progress.
01 hex: Auto-negotiation and speed detection failed.
02 hex: Auto-negotiation failed, but speed detection succeeded.
03 hex: Speed and duplex mode negotiation succeeded.
04 hex: Auto-negotiation was not attempted.
Always FALSE: Changes can be applied automatically.
Always FALSE
Read/write data
Attrib-
Data
ute
type
Read
Struct
---
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
ULINT
Reads the current value.
Description
NX-series EtherNet/IP Unit User's Manual (W627)
Value