dummyhead
dummyhead
IGNITION SYSTEM INSPECTION
• If there is no spark at the plug, check all connections
for loose or poor contact before measuring the peak
voltage.
• Use a commercially available digital multimeter with
an impedance of 10 MΩ/DCV minimum.
• The display value differs depending upon the
internal impedance of the multimeter.
• If using the Imrie diagnostic tester (model 625),
follow the manufacturer's instructions.
Connect the peak voltage adaptor [1] to the digital
multimeter [2], or use the Imrie diagnostic tester.
TOOL:
Imrie diagnostic tester (model 625) or
Peak voltage adaptor
with commercially available digital multimeter
(impedance 10 MΩ/DCV minimum)
07HGJ-0020100
IGNITION SYSTEM
[1]
[2]
5-7