Lenovo 7D9F Manual page 62

Messages and codes reference
Hide thumbs Also See for 7D9F:
Table of Contents

Advertisement

2. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
Note: If the device is part of a cluster solution, verify that the latest level of code is supported by the
cluster solution before the update.
3. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
• FQXSPIO0014J: Bus [SensorElementName] is operating in a degraded state.
This message is for the use case when an implementation has detected a Bus is Degraded.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0246
User Action:
Complete the following steps until the problem is solved:
1. Collect Service Data log.
2. Contact Lenovo Support.
• FQXSPIO0015M: Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected a Fault in a slot.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0330
User Action:
Complete the following steps until the problem is solved:
1. Reseat the affected adapters and riser card.
2. Update the server firmware (UEFI and XCC) and adapter firmware.
Note: Some cluster solutions require specific code levels or coordinated code updates.
3. If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster
solution before the update.
4. Replace the affected adapters.
5. Replace the riser card.
6. (Trained service technicians only) Replace the processor board.
• FQXSPIO0017I: Package installed in slot [PhysicalConnectorElementName] for system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected a Package was Installed in a slot.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
58
ThinkSystem SR655 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9eThinksystem sr655 v3

Table of Contents