Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0530
User Action:
Complete the following steps until the problem is solved:
1. AC cycle the system.
2. If the problem persist collect Service Data log.
3. Contact Lenovo Support.
• FQXSPPW0088J: Sensor [SensorElementName] has indicated an install error.
This message is for the use case when an implementation has detected a Sensor install error.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0556
User Action:
Complete the following steps until the problem is solved:
1. Review system specific jumper settings and identify security jumper located in the product guide.
Note: Before you change any switch settings or move any jumpers, turn off the server; then,
disconnect all power cords and external cables.
2. Confirm that the security jumper is present and in correct position.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPPW0091I: Redundancy [RedundancySetElementName] has been restored.
This message is for the use case when an implementation has detected Redundancy was Restored.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0561
User Action:
Information only; no action is required.
• FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
108