SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Complete the following steps until the problem is solved:
1. Check if one of the power supplies is missing, failed, or not installed properly. If so, reinstall it.
2. Check the maximum power supply rate and power capping policy. If any power supply does not meet
the requirements, change the power supply or modify the power capping mechanism.
3. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
Note: If the device is part of a cluster solution, verify that the latest level of code is supported by the
cluster solution before the update.
4. Collect service data log from the XCC WebGUI and contact Lenovo Support.
• FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
Complete the following steps until the problem is solved:
1. Check the PSU LED:
a. If AC LED is not lit, check the power cord and input voltage.
b. If DC LED is not lit, remove and then reinstall the power supply.
2. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
• FQXSPPW0110M: Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0810
User Action:
Complete the following steps until the problem is solved:
1. Check if one of the power supplies is missing, failed, or not installed properly. If so, reinstall it.
2. Check the maximum power supply rate and power capping policy. If any power supply does not meet
the requirements, change the power supply or modify the power capping mechanism.
3. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
.