Lenovo 7D9F Manual page 121

Messages and codes reference
Hide thumbs Also See for 7D9F:
Table of Contents

Advertisement

User Action:
Complete the following steps until the problem is solved:
1. Reboot the system and confirm that the drive is still in failed state.
2. Collect Service Data log.
3. Contact Lenovo Support.
• FQXSPSD0002G: Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Complete the following steps until the problem is solved:
1. Check if there is any drive failure.
2. If yes, replace the failed drive.
3. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
• FQXSPSD0002L: Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has a fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps until the problem is solved:
1. Check Lenovo Support (http://support.lenovo.com/) for service bulletins and Tech tips and firmware
update related to your drive.
2. Look for any other RAID-related errors.
3. Replace the drive.
• FQXSPSD0003G: Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
.
Chapter 2
XClarity Controller events
117

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9eThinksystem sr655 v3

Table of Contents