Lenovo 7D9F Manual page 107

Messages and codes reference
Hide thumbs Also See for 7D9F:
Table of Contents

Advertisement

b. if DC LED is not lit, remove and re-install power supply
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPPW0007I: Power supply [arg1] in the enclosure/chassis (MTM-SN: [arg2])has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0100
User Action:
Complete the following steps until the problem is solved:
1. Check if the storage enclosure has lost input power.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0104
User Action:
Complete the following steps until the problem is solved:
1. Check if the PSUs are the same power rating (wattage).
2. Check if the PSUs are the same efficiency level.
3. Check if the PSUs are supported by the platform.
4. If problem persists, collect Service Data log.
5. Contact Lenovo Support.
• FQXSPPW0008I: [SensorElementName] has been turned off.
This message is for the use case when an implementation has detected a Power Unit that has been
Disabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Power Off
SNMP Trap ID: 23
CIM Prefix: PLAT CIM ID: 0106
User Action:
.