Lenovo 7D9F Manual page 122

Messages and codes reference
Hide thumbs Also See for 7D9F:
Table of Contents

Advertisement

Complete the following steps until the problem is solved:
1. Check if there is any drive failure.
2. If yes, replace the failed drive.
3. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
• FQXSPSD0003I: Hot Spare enabled for [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required.
• FQXSPSD0005I: Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required.
• FQXSPSD0005L: Array [ComputerSystemElementName] is in critical condition.
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0174
User Action:
Complete the following steps until the problem is solved:
1. Collect Service Data log and RAID log from the XCC WebGUI.
2. Contact Lenovo Support.
• FQXSPSD0006L: Array [ComputerSystemElementName] has failed.
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
118
ThinkSystem SR655 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9eThinksystem sr655 v3

Table of Contents