Lenovo 7D9F Manual page 178

Messages and codes reference
Hide thumbs Also See for 7D9F:
Table of Contents

Advertisement

3. Check Lenovo Support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.
Note: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings
-> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
4. If the problem persists, collect Service Data logs.
• FQXSFIO0021J: PCIe Error Recovery has occurred in physical [arg1] number [arg2]. The [arg3] may
not operate correctly.
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0022J: PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3] number
[arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0023J: PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3] number
[arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo Support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
174
ThinkSystem SR655 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9eThinksystem sr655 v3

Table of Contents