• FQXSPSD0008L: Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any hard disk drive that is indicated by lit status.
2. Recreate the array.
3. Restore the date from backup.
• FQXSPSD0009M: The System [ComputerSystemElementName] encountered firmware error -
unrecoverable boot device failure.
This message is for the use case when an implementation has detected that System Firmware Error
Unrecoverable boot device failure has occurred.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0770
User Action:
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged BMC
message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the
Information Center for the appropriate user response.
• FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Complete the following steps until the problem is solved:
1. If drive was intentionally removed, make sure that there is a filler in the drive bay.
2. Make sure that the drive is correctly seated.
3. If drive is correctly seated, replace the drive.
• FQXSPSD2001I: The [StorageVolumeElementName] has recovered from a fault.
This message is for the use case when an implementation has detected a Drive was Enabled.
120