2. Remove all the connected USB devices connected to the USB controller according to system spec
and reboot the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0001I: DIMM [arg1] Disable has been recovered. [arg2]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0001M: DIMM [arg1] has been disabled due to an error detected during POST. [arg2]
Severity: Error
User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and enable the DIMM (For AMD, do not need to enable DIMM in Setup). Reboot the
system.
3. Update UEFI firmware to the latest version.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0002I: The uncorrectable memory error state has been cleared.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0002M: An uncorrectable memory error has been detected on DIMM [arg1] at address
[arg2]. [arg3]
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
memory error.
2. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
3. Swap the affected DIMM to another known good slot and verify whether the issue still be observed or
not.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0006I: [arg1] DIMM [arg2] has been detected, the DIMM serial number is [arg3].
Severity: Info
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does have unqualified memory
installed.
2. The memory installed may not be covered under warranty.