2. Reseat the DIMM in the slot specified by the event message.
3. Restore A/C power and power on the system.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0050G: DRAM PFA threshold limit exceeded on DIMM [arg1] sub-channel [arg2] Rank
[arg3] DRAM [arg4], DIMM identifier is [arg5].
Severity: Warning
User Action:
Complete the following steps:
1. Power off the system and remove the A/C power.
2. Reseat the affected DIMM.
3. Restore the A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0057G: Page Retire PFA Threshold limit exceeded on DIMM [arg1] at address [arg2].
[arg3] [arg4]
Severity: Warning
User Action:
Complete the following steps:
1. Power off the system and remove the A/C power.
2. Reseat the affected DIMM.
3. Restore the A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0067G: Errors per row counter threshold limit exceeded on DIMM [arg1] sub-channel
[arg2] Rank [arg3] DRAM [arg4], need to restart the system for DIMM Self-healing to attempt post
package repair (PPR), DIMM identifier is [arg5].
Severity: Warning
User Action:
Complete the following steps:
1. Restart the system to allow for DIMM Self-healing to attempt hard post package repair (PPR) and
confirm that event ID FQXSFMA0026I was recorded.
2. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
3. If the problem persists or if PPR attempt failed due to event ID FQXSFMA0027M or
FQXSFMA0028M, collect Service Data logs and contact Lenovo Support.
• FQXSFPU0018N: CATERR(IERR) has asserted on processor [arg1].
Severity: Error
User Action: