Download Print this page

Toshiba T4700CS Maintenance Manual page 27

Advertisement

Adapter (AC Adapter or DeskStation)
Status
P01
P02
Battery
Status
P10
VCC Output
Status
P20
P21
P22
B3V Output
Status
P30
P31
P32
P33
Output Voltage (12V or M12V)
Status
P40
P41
P42
Power Supply Microprocessor
Status
P50
P52
T4700CS, T4700CT, T4800CT
AC Adapter Voltage is over the maximum allowed limit.
Desk Station Voltage is over the maximum allowed limit.
Charge current is over the maximum allowed limit.
VCC Voltage is over the maximum allowed limit.
VCC Voltage is below the minimum allowed limit.
VCC Voltage is out put at a low level (does not fall to zero) while
the power is off.
B3V Voltage is over the maximum allowed limit.
B3V Voltage is below the minimum allowed limit.
B3V Voltage is not within the normal range while the system is on.
B3V Voltage is not within the normal range while the system is in
the resume mode.
12V Voltage is over the maximum allowed limit.
12V Voltage is below the minimum allowed limit.
M12V Voltage is not within the normal range.
Firmware error.
Program error.
Meaning
Meaning
Meaning
Meaning
Meaning
Meaning