Hisense YXE-A03U Technical & Service Manual page 79

Wired controller/central controller/control box
Table of Contents

Advertisement

3. Central Controller(YXE-C03U(E))
Self-setting Parameters
The internal parameters of the wired controller
can be set with the actual usage conditions.
The catalogue of custom-setting parameters is
shown as follows:
Self-setting
Parameter
Implication of Code Display
Code
01
Version No.
03
boot
Integrated control Baud rate
04
setting
Is remote control/button
05
operation setting permited
or not
06
Temperature display setting
Fahrenheit degree display
07
setting
08
Cooling-only setting
Temperature limits revision
10
setting
Environment temperature
11
revision setting
13
Number of slaves
14
Outdoor unit capacity
The maximum allowable
15
deviation of the master-
slave coil
The method of setting the self-setting parameters
3
1
确 定
2
1. Hold down "ADD.FUNC" and "ON/OFF"
buttons at the same time for 3s, the buzzer will
beep for four times to alert that it goes into the
parameter self-setting mode, and the screen
will display the self-setting parameter code.
2. Press the "
" button (plus) or "
(minus) to adjust the self-setting parameter
code that is required to be set, and press the
"ENTER" button, with the function code
displayed in flickering.
3. Press the "
" (plus) button or "
button to adjust the function code, press the
"ENTER" button to confirm the parameter, and
then the setting is completed.
How to exit:
Press "Cancel" or "ON/OFF" button to exit when
any self-setting code is displayed.
Description
Remarks
Restore factory default
0-9600bps;1-19200bps;
2-38400bps;3-76800bps
The factory
0-Remote control/button
permitted;
setting
1-Remote control prohibited;
defaults to 0
2-Button prohibited;
3-Remote control/button
prohibited .......
see the table3 on the right for
more content
0-Display the set temperature;
1-Display the indoor environment
temperature
0-Display in degree centigrade;
1-Display in Fahrenheit degree
0-Heat pump type air
conditioner;
1-Cooling-only air conditioner
0-Not permitted;1-Permitted
0-Not permitted;1-Permitted
The factory
0-No slave; 1–One slave; 2–Two
setting
slaves; 3–Three slaves
defaults to 1
0-1-100W, 2-200W, N-N*100W,
The factory
which automatically matches with
setting
the indoor unit capacity
defaults to 0
The factory
setting
N-Deviation value.
defaults to
20
Self-setting
parameter code
Function code
1
" button
" (minus)
NO
0 Remote control/button permitted
1 Remote control prohibited
2 Button prohibited
3 Remote control/button prohibited
5 Turning ON/OFF by remote control prohibited
13 Turning on by remote control & MODE setting prohibited
17 Temperature setting by remote control prohibited
Temperature setting by remote control prohibited &
21
ON/OFF setting prohibited
Temperature setting by remote control prohibited &
25
MODE setting prohibited
Temperature setting by remote control prohibited &
29
MODE setting & ON/OFF setting prohibited
33 Fan speed setting prohibited
37 Fan speed & ON/OFF setting prohibited
41 Fan speed & MODE setting prohibited
45 Fan speed & MODE & ON/OFF setting prohibited
49 Fan speed & temperature setting prohibited
53 Fan speed & temperature & ON/OFF setting prohibited
57 Fan speed & temperature & MODE setting prohibited
Fan speed & temperature & MODE & ON/OFF setting
61
prohibited
65 Swing setting prohibited
69 Swing & ON/OFF setting prohibited
73 Swing & MODE setting prohibited
77 Swing & MODE & ON/OFF setting prohibited
81 Swing & temperature setting prohibited
85 Swing & temperature & ON/OFF setting prohibited
89 Swing & temperature & MODE setting prohibited
Swing & temperature & MODE & ON/OFF setting
93
prohibited
97 Fan speed & swing setting prohibited
101 Fan speed & swing & ON/OFF setting prohibited
105 Fan speed & swing & MODE setting prohibited
Fan speed & swing & ON/OFF & MODE setting
109
prohibited
113 Fan speed & swing & temperature setting prohibited
Fan speed & swing & temperature & ON/OFF setting
117
prohibited
Fan speed & swing & temperature & MODE setting
121
prohibited
Fan speed & swing & temperature & ON/OFF & MODE
125
setting prohibited
77
Table 3