Hisense YXE-A03U Technical & Service Manual page 63

Wired controller/central controller/control box
Table of Contents

Advertisement

2. Wired Controller(YXE-E01U(E)/YXE-E02U(E))
Indoor unit capacity
11
setting
Ratio of indoor unit
body temperature
12
(heating mode)
Temperature adjustment-
13
cooling
Temperature
14
adjustment-heating
15
Indoor unit address
16
System address
17
Group address
Self-recovery of cooling/
18
heating temperature limit
Minimum cooling
19
temperature setting
Maximum heating
20
temperature setting
21
VIP setting
Group control
22
temperature effective
setting
Static pressure positive
23
compensation gear of
DC fan
Static pressure negative
24
compensation gear of
DC fan
Access control, fire
25
protection, ON/OFF
function set
28
Deep cool mode
1. Setting mode of unit/ frematch:0-255, actual
value= indicated value * 100(W).
2. VRF setting mode:
0 = 3500W;1 = 2200 W;2 = 2500 W;3 = 2800
W
4 = 3200 W;5 = 3600 W;6 = 4000 W;7 = 4600
W
8 = 5000 W;9 = 5600 W;10 = 6300 W;11 =
7100 W
12 = 8000 W;13 = 11200 W;14 = 14000 W;15
= 24000 W
0~10valid, more than 10 default is 10 0:0%;
1:10%;...;10:100%
-10~10℃ (single character with symbol)
-10~10℃ (single character with symbol)
Address= set value
Address= set value
Address= set value
=0, cooling/ heating temperature limit is invalid;
=1, cooling temperature limit is valid, heating
temperature limit is invalid.
=2, heating temperature limit is valid, cooling
temperature limit is invalid.
=3, cooling/ heating temperature limit is valid.
Set value= actual temperature(16℃-30℃)
Set value= actual temperature(16℃-30℃)
=0, no VIP;
=1, set to VIP
=0, group control temperature effective
=1, Group control temperature effective
0~3 gears, the default is 0 gears, no compensation;
The 3rd gear is the highest gear of static pressure,
and the corresponding compensation speed is set
for the 1
st
to 3
rd
gears in the indoor EE.
0~3 gears, the default is 0 gears, no compensation;
The 3rd gear is the lowest gear of static pressure,
and the corresponding compensation speed is set
for the 1
to 3
gears in the indoor EE.
st
rd
=0, access control, fire protection functions are all
invalid;
=1, access control function is valid;
=2, fire protection function is valid;
=3, access control, fire protection are all valid;
=4, ON/OFF function are all valid.
0:Deep cool mode is invalid;
1:Deep cool mode is valid.
61
0:entirely use temperature
sensed by wired remote
controller;
10:entirely use temperature
sensed by indoor unit
Temperature displayed on
wired controller
Temperature displayed on
wired controller
is invalid;
is valid