2. Wired Controller(YXE-E01U(E)/YXE-E02U(E))
Read the operating parameters of indoor unit
The internal parameters of the air conditioner can be set with the following method
Instruction
1.
Press and hold the "
for 3s at the same time to enter the parameter
self-setting state, Then the "
icon will be always on.
2.
Press the "
" / "
or decrease the root address as 2.
3. Press the "
" / "
decrease the sub-address, and select the desired
sub-address value.
4.
Press the "
" button to exit without settings.
The catalogue of custom-setting parameters is shown as follows:
Sub-address
parameter code
00
Slave unit model
01
Indoor unit model
02
Outdoor unit model
03
Program version number of indoor unit
04
Indoor unit capacity code
05
Program version number of outdoor unit
06
Return air temperature of indoor unit
07
Indoor unit coil temperature
08
Outdoor ambient temperature
09
Compressor exhaust temperature
10
Compressor return air temperature
11
Outdoor condenser temperature
12
Compressor discharge pressure
13
Compressor suction pressure
Outdoor unit electronic expansion valve
14
opening
15
AC input current
16
Effective value of AC voltage
17
Indoor unit built-in EE
18
Indoor unit external EE
19
Outdoor unit built-in EE
20
Outdoor unit external EE
21
Clock
22
Time-lapse function status
Wire controller sampling indoor ambient
23
temperature
24
Fault code
25
Drive board fault code
26
Air outlet temperature of indoor unit
Indoor unit electronic expansion valve
27
opening
28
Compressor current
29
Indoor unit body temperature
30
Inlet temperature of indoor unit coil
31
Outlet temperature of indoor unit coil
32
Inlet temperature of outdoor condenser
33
Outlet temperature of outdoor condenser
" and "
" button
" and "
" button to increase
" button to increase or
Parameter description
"
sub-address+
root address+
3
root address- sub-address-
YXE-E01U(E)
Parameter
Parameter description
code
Indoor unit address
34
System address
35
Local indoor unit address
36
Outdoor unit operation mode
37
Number of outdoor units started
38
Number of indoor units started
39
Number of indoor units allocated during automatic
40
allocation
Target frequency
41
Driving frequency
42
Outdoor unit defrosting temperature
43
Target defrosting temperature
44
Water inlet temperature of water module
45
Water outlet temperature of water module
46
Temperature after indoor electric heating
47
Inlet temperature of gas replenishment and enthalpy
48
increase
Outlet temperature of gas replenishment and enthalpy
49
increase
Inlet temperature of water heater
50
Outlet temperature of water heater
51
Water heater temperature1
52
Water heater temperature2
53
Computing power requirements
54
Target speed of fan1
55
Target speed of fan2
56
57
Actual speed of fan1
Actual speed of fan2
58
Indoor target speed
59
Indoor actual speed
60
Opening of air replenishment enthalpy increasing
61
valve
Indoor unit characteristic code
63
Registration code
64
Registration information
65
Network D information
66
59
.
Parameters value code
root address sub-address
root address+ sub-address+
1
root address- sub-address-
YXE-E02U(E)
1
3