Hisense YXE-A03U Technical & Service Manual page 31

Wired controller/central controller/control box
Table of Contents

Advertisement

2. Wired Controller(YXE-C01U1(E))
Self-setting Parameters
The internal parameters of the wired controller can be
set with the actual usage conditions.
The catalogue of custom-setting parameters is shown
as follows:
Custom-
setting
Implication of Code
Parameter
Display
Code
01
Version No.
03
boot
0-Remote control/button permitted;
1-Reserved;
Is remote
2-Button prohibited;
control/button
05
3-Remote control/button prohibited
operation setting
permitted or not
0-Display the set temperature;
Temperature display
06
1-Display the indoor room
setting
temperature
Temperature
0- Display in Celsius;
07
measurement unit
1- Display in Fahrenheit degree
display setting
Cooling-only setting 0-Heat pump type air conditioner;
08
1-Cooling-only air conditioner
Temperature limits
10
0-Prohibited; 1-Permitted
revision setting
Room temperature
11
0-Prohibited; 1-Permitted
revision setting
The Method of Setting the Custom Parameters
2
.
.
ADD
FUNC
1
TIMER/CLOCK
SWING
ENTER
FAN
CANCEL
2
1. Press and hold "ADD. FUNC." and "ON/OFF"
buttons at the same time for 3s, to access the
custom-setting mode, and the custom-setting
parameter code will flicker on the screen.
2. Press the "
" button (plus) or "
select the custom-setting parameter code that is
required to be set, and press the "ENTER" button,
with the function code displayed flickering.
3. Press the "
" (plus) button or "
select the function code, and press "ENTER" button
to confirm the setting.
How to exit:
Press "Cancel" button to exit when any custom-setting
code is displayed.
Parameter Setting
When the wired controller is set to display the room
temperature, the temperature setting limit can be revised
if needed. Before setting, please check if these parameters
are enabled to be revised. For details, see Custom-setting
parameters.
Description
Restore factory default
.......
see the table3 on the right for
more content
Custom-setting Parameter Code
Function Code
ON/OFF
1
MODE
3
SLEEP
" button (minus) to
" (minus) button to
NO
0 Remote control/button permitted
1 Remote control prohibited
Remarks
2 Button prohibited
3 Remote control/button prohibited
5 Turning ON/OFF by remote control prohibited
13 Turning on by remote control & MODE setting prohibited
17 Temperature setting by remote control prohibited
Temperature setting by remote control prohibited &
21
ON/OFF setting prohibited
Temperature setting by remote control prohibited &
25
MODE setting prohibited
The
Temperature setting by remote control prohibited &
factory
29
MODE setting & ON/OFF setting prohibited
setting
defaults to
33 Fan speed setting prohibited
0
37 Fan speed & ON/OFF setting prohibited
41 Fan speed & MODE setting prohibited
45 Fan speed & MODE & ON/OFF setting prohibited
49 Fan speed & temperature setting prohibited
53 Fan speed & temperature & ON/OFF setting prohibited
57 Fan speed & temperature & MODE setting prohibited
Fan speed & temperature & MODE & ON/OFF setting
61
prohibited
65 Swing setting prohibited
69 Swing & ON/OFF setting prohibited
73 Swing & MODE setting prohibited
77 Swing & MODE & ON/OFF setting prohibited
81 Swing & temperature setting prohibited
85 Swing & temperature & ON/OFF setting prohibited
89 Swing & temperature & MODE setting prohibited
Swing & temperature & MODE & ON/OFF setting
93
prohibited
97 Fan speed & swing setting prohibited
101 Fan speed & swing & ON/OFF setting prohibited
105 Fan speed & swing & MODE setting prohibited
Fan speed & swing & ON/OFF & MODE setting
109
prohibited
113 Fan speed & swing & temperature setting prohibited
Fan speed & swing & temperature & ON/OFF setting
117
prohibited
Fan speed & swing & temperature & MODE setting
121
prohibited
Fan speed & swing & temperature & ON/OFF & MODE
125
setting prohibited
29
Table 3
Description

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Hisense YXE-A03U

Table of Contents