Hisense YXE-A03U Technical & Service Manual page 15

Wired controller/central controller/control box
Table of Contents

Advertisement

2. Wired Controller(YXE-A03U(E))
Self-setting Parameter
The internal parameters of the wired remote controller can be set with the actual usage conditions.
Methods to set custom-setting parameters:
1. Hold down mode button
setting state, then custom-setting parameter codes will display in the temperature display area;
2. Press
or
button to adjust to the custom-setting parameter code to be set, press timer button
to enter the state to set this parameter, then its function code will flicker;
3. Press
or
button to adjust the function code and press timer button
setting is completed.
The custom-setting parameters list is shown as below:
Custom-setting
Implication of Code Display
Parameter Code
01
03
Remote control/button operation setting
05
06
Temperature display setting
Temperature measurement unit display
07
08
Cooling only setting
13
14
and timer button
Version No.
boot
Restore factory setting
00-Remote control/button operation is enabled;
01-Remote control is disabled;
is allowed or not
02-Button operation is disabled;
03-Remote control/button operation is disabled.
00-Display the set temperature;
01-Display the indoor environment temperature
00-Display in Celsius;
setting
01-Display in Fahrenheit degree
00-Heat pump type air conditioner;
01-Cooling only air conditioner
00-Buzzer is valid;
Buzzer setting
01-Buzzer is invalid
00-Backlight is valid;
Backlight setting
01-Backlight is invalid
for 3s simultaneously to enter parameters custom-
Description
13
to confirm, then the
Remarks
The factory
setting
defaults to 0