Hisense YXE-A03U Technical & Service Manual page 32

Wired controller/central controller/control box
Table of Contents

Advertisement

2. Wired Controller(YXE-C01U1(E))
1.Room Temperature Correction
Setting of room temperature correction is for
particular cases (e.g. installation location is
near a marble wall): when the wired controller
is set to display the room temperature, but the
room temperature detected is different from the
actual one, so setting correction is necessary.
.
.
ADD
FUNC
1
TIMER/CLOCK
SWING
CANCEL
2
Room Temperature Correction
Setting Method:
1. Under OFF conditions, press the " " or
" " button to display the
2. Hold down the "ADD.FUNC" for 3s, the buzzer
will beep for four times to alert that it goes into the
room temperature modification state. The
room temperature value and icon
flickering at the same time.
3. Press the "
" (plus) button or "
button to select the room temperature value
within an offset of ±10℉/℃ of the current
temperature, press the "ENTER" button to confirm
the setting, save the setting and exit.
How to cancel:
In room temperature correction mode,
press "CANCEL" button to cancel correction and
exit.
Press any other button (except MODE button) to
exit from room temperature correction directly.
2.Temperature Limit Setting
Default temperature range is (61-86)℉[(16-30)℃].
You can change the range when needed.
For example, in cooling mode, temperature
adjustment range could be changed to (73-86)℉
[(23-30)℃]; in heating mode, it could be changed
to (61-73)℉ [(16-23)℃]. The temperature limit is
only effective for the cooling and heating modes.
Setting method:
1. Under OFF conditions, press down the
"
" (plus button) or "
to adjust the wired remote controller to display .
2. Hold down the "ADD. FUNC." button for 3s,
and the buzzer will beep for four times to alert
that it goes into the set temperature limit
state. The wired remote controller's limit
temperature value and icon will flicker.
3. Press the "
" button (plus) or "
(minus) to adjust the temperature limit value
2
ON/OFF
FAN
ENTER
MODE
3
SLEEP
icon.
start
" (minus)
" (minus button)
" button
within the range of (61~86)
you press the "MODE" button, it will change in the
following sequence:
COOLING
DRY
Press "ENTER" button to save the change and exit.
After setting, the limit temperature icon and l
numerical value icons stop flickering.
30
[(16-30) ], and if
FAN
HEATING
AUTO

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Hisense YXE-A03U

Table of Contents