Hisense YXE-A03U Technical & Service Manual page 72

Wired controller/central controller/control box
Table of Contents

Advertisement

3. Central Controller(YXE-C03U(E))
4. After TIMER ON/OFF setting is completed, press "
(plus) or "
" (minus) to select the desired day, press
"ENTER" button to confirm it, or press "CANCEL" button to
cancel. The selected day will be marked with " ".
For example,
selected are effective.
5. Continue group 2 setting, repeat the same setting procedure
as group 1. Four groups timer ON/OFF can be set at most.
6. You can quit WEEKLY TIMER setting by pressing "TIMER/
CLOCK" or "ON/OFF" button when group number flickering.
Weekly timing inquiry
When the weekly TIMER function is available, it will go into the weekly timing inquiry if you press the
"TIMER" button. Press the plus button "
timer moment.
NOTE:
If need to temporarily leave for a few days when weekly timer has been set, meanwhile timer
ON/OFF is not permitted to work and continue to work after you are back, you can hold down "ON/OFF"
button for 3 seconds to turn it off completely. At this moment, weekly timer set time can still be saved,
but the air conditioner will not run.
Weekly timer setting resolution is 1 minute. Timer ON/OFF signal is effective within 1 minute.
Buzzer Indicator Selection
Default buzzer indicate during operation. If mute operation is needed,
hold down "FAN" button for 3 seconds, the buzzer beeps for 4 times,
indicating setting has been successfully changed.
If you need it return to normal, repeat the steps above.
Dimmer setting
The screen is bright by default. If you need the screen to be dark,
hold down"MODE" button for 3seconds, the buzzer beeps for 4
times indicating the setting has been successfully changed.
If you need it return to normal, repeat the steps above.
Filter clean resetting
(Available for models equipped with filter clean function and need operate by professional staff)
When
displays on LCD, it indicates that the filter needs to be
cleaned.
Please contact professional stuff to do filter cleaning. After the
cleaning, hold down "CANCEL" button for 3 seconds, the buzzer
beeps for 4 times indicating FILTER CLEAN has been successfully
reset.
NOTE:
FILER CLEAN screen prompt is only effective for some models. For details, please refer to indoor unit
manuals. Be sure to stop the operation and turn off the power supply before performing any cleaning.
shows 7 days of a week all
" or minus button "
70
"
TIMER day select
" to inquire the previous or the next

Hide quick links: