2.3 System Configuration and Power-on

Be sure to turn OFF the host computer, and not to connect the E10A-USB emulator and the host computer by a USB cable. Then, follow the
procedure below.
1.
Attach the user interface cable to the connector on the target side of the E10A-USB emulator.
2.
Attach a USB cable to the connector on the host side of the E10A-USB emulator.
3.
Turn on the host computer (Start the operating system).
4.
Turn on the M3A-HS19 CPU board.

2.4 Disconnect the System Power Supply

Follow the procedure below to disconnect the system power supply.
1. Disconnect the E10A-USB emulator from the High-performance Embedded Workshop.
2. Turn off the M3A-HS19 CPU board.
3. Exit the High-performance Embedded Workshop, and turn off the host computer.
Unless the above power-on sequence is followed, unrecoverable damage may occur to the
M3A-HS19 or the E10A-USB emulator or both.
Rev. 1.00 July 11, 2008
REJ10J1328-0100
2.3 System Configuration and Power-on
CAUTION
Setting Up the Hardware
2-4