To view RMON history information:
1. Click Statistics/RMON > RMON History > History Control. The History Control Page
opens:
Figure 5-99
The History Control Page contains the following fields:
History Entry No. – Displays the entry number for the History Control Table page.
Source Interface – Displays the interface from which the history samples were taken. The
possible field values are:
Port – Specifies the port from which the RMON information was taken.
LAG – Specifies the LAG from which the RMON information was taken.
Sampling Interval – Indicates in seconds the time that samples are taken from the ports.
The field range is 1-3600. The default is 1800 seconds (equal to 30 minutes).
Samples Requested – Displays the number of samples to be saved. The field range is 1-
65535. The default value is 50.
Current Number of Samples in List– Displays the current number of samples taken.
5-138