Ricoh FT5535 Service Manual page 680

Hide thumbs Also See for FT5535:
Table of Contents

Advertisement

SERVICE PROGRAM MODE
Mode No.
Forced Process
Control
3-902
Exposure Lamp
Voltage
Adjustment †
4-001
Exposure Lamp
Voltage Display
°4-002
Vertical
Magnification
Adjustment †
4-008
A212/A214
CÓPIA NÃO CONTROLADA
Function
Performs the 1,000-copy process control
cycles forcibly.
initial adjustment → V
V
SG
detection → V
V
L
ADS
adjustment
This mode starts after the
pressed.
Adjusts the exposure lamp voltage
(0.5 V per step [Range: 50.0 V to 75.0 V])
For 115 V machines, the actual applied
voltage = displayed value x 1.1412.
After doing this SP mode, ADS initial
setting (SP4-201) and forced V
detection (SP3-105) must also be
done.
See "Replacement and Adjustment -
Copy Quality Adjustments" for how to
adjust.
Displays the current exposure lamp
voltage.
(0.5 V per step [Range: 50.0 V to 85.0 V])
For 115 V machines, the actual applied
voltage = displayed value x 1.1412.
Adjusts the magnification in the paper
travel direction.
(0.1% per step [Range: –1.6% to +1.6%])
See "Replacement and Adjustment -
Copy Quality Adjustments" for how to
adjust.
5-50
CÓPIA NÃO CONTROLADA
detection →
R
(pattern)
!
key is
50.0 ~ 75.0 V
Default = 63 V
L
50.0 ~ 85.0 V
0 ~ 32 V
Default = 16 ‡
Settings
SM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents