13.2 REGULAR PM PROCEDURE
1. Make a Copy
2. Optics (every 120 k)
3. Around the Drum
(every 120 k)
Replace the
pick-off pawls
(every 240 k).
SM
CÓPIA NÃO CONTROLADA
PREVENTIVE MAINTENANCE SCHEDULE
Make a copy of an OS-A3 test chart at manual
image density level 4.
1. Clean the mirrors, lens, and reflectors with a
soft cloth, cotton pad with water, or a blower
brush.
2. Clean the exposure glass with alcohol or glass
cleaner.
3. Clean the scanner guide rail with a dry cloth.
4. Clean the lens block guide rail with a dry cloth.
5. Clean the ADS sensor and the original width
and length sensors
6. Inspect the exposure lamp.
7. Clean the dust filter.
1. Remove the drum and clean the ID sensor
with a blower brush.
2. Clean the pick-off pawls.
3. Clean the quenching, erase, and pre-transfer
lamps with a dry cloth. Discharge any static
electricity before putting them back.
4. Put back the drum.
5. Replace the drum charge roller, drum charge
roller cleaner, and drum charge roller terminal
and roller terminal.
1-97
CÓPIA NÃO CONTROLADA
Every 120 k (A204/A206/A207),
or 100 k (A208/A210/A211)
Every 240 k (A204/A206/A207),
or 200 k (A208/A210/A211)