11. Remove the scanner motor belt [A] by
removing the pulley [B] (1 Allen screw).
12. Remove both bearings [C] (1 E-ring each).
13. Remove the left cover and swing the main switch bracket [D] out of the way.
14. Slide the front pulley to the cutout [E] of the front frame and remove all four
scanner drive belts.
NOTE: When reinstalling, make sure of the following points:
If the pulleys [F] have been removed, make sure that they face the
same direction as shown when you put them back.
The belt tension bracket should be tightened after all the belt tension
springs have been installed.
Adjust the position of the 1st and 2nd scanner by using the positioning
bracket kit. (See Scanner Positioning Adjustment.)