Rev. 7/95
3. DEVELOPMENT AND TONER SUPPLY
3.1 DEVELOPMENT UNIT REMOVAL
[D]
[B]
[A]
1. Turn off the main switch.
2. Open the front cover.
3. Remove the knob screw [A].
4.
Swing out bottle holder [B] and
Then slide out the bottle holder assembly [D] and
holder assembly.
5. Remove the knob screw [E] and disconnect the connector [F].
6. Press down the development unit lock lever [G] and pull out the development
unit [H]. Then place it on a clean sheet of paper.
A156/A160/A162
CÓPIA NÃO CONTROLADA
[C]
[G]
pull down the lock lever [C].
5-12
CÓPIA NÃO CONTROLADA
[H]
[F]
[E]
swing out the bottle
FSM