E191: Auto ID sensor adjustment error (at the 1K copies process
control)
- Definition - [D]
1. ADS sensor output is lower than the 2.7 V target at the maximum gain for
the sensor.
2. ADS sensor output is higher than the 2.7 V target at the minimum gain for
the sensor.
- Possible Causes -
ADS sensor board defective
ADS sensor board poorly connected
Main control board defective
E302: Drum charge roller current leak
- Definition - [B]
A charge current leak signal is detected.
- Possible Causes -
Drum charge roller unit defective
CB high voltage supply board defective
E346: Development bias leak
- Definition - [B]
A development bias leak signal is detected.
- Possible Causes -
Sleeve roller receptacle damage
CB high voltage supply board defective
E351: ID sensor adjustment error
- Definition - [D]
When the ID sensor output (V
(3.8 ~ 4.2 V) during the process control self check.
- Possible Causes -
ID sensor board defective
Dirty ID sensor
Main control board defective