Ricoh FT5535 Service Manual page 499

Hide thumbs Also See for FT5535:
Table of Contents

Advertisement

Mode No.
CPM Down
Select †
(Type 1 only)
1-801
Jogger Span
Adjustment
1-902
(Side Fence) †
Jogger Span
Adjustment
1-905
(End Fence) †
Drum Charge
Voltage
Adjustment
2-001
(for copying) †
Drum Charge
Voltage Display
2-002-001
to
2-002-002
Drum Charge
Voltage
Adjustment
2-003
(for making V
patterns) †
SM
CÓPIA NÃO CONTROLADA
Function
If this is set to 1 or 2, the machine drops
the cpm to the same as the Type 2
model if it detects a temperature lower
than the setting. This allows the roller to
warm up again, to prevent poor fusing.
This feature may be needed in areas
where the mains voltage is a bit lower
than the rating (for example, in areas of
Europe where the mains is 210 V,
instead of 220 - 240 V).
Adjusts the stop position of the jogger
side fence span of the duplex unit.
(0.5 mm per step [Range: –8.0 mm to
+8.0 mm])
A207 and A211 copiers only
Adjusts the stop position of the jogger
end fence span of the duplex unit.
(0.5 mm per step [Range: –8.0 mm to
+8.0 mm])
A207 and A211 copiers only
Adjusts the voltage applied to the drum
charge roller during copying.
The adjustment factor set with this SP
mode is added to the base voltage.
(30 V per step [Range: Base voltage
–480 V to Base voltage + 480 V])
Displays the voltage applied to the drum
charge roller.
SP2-002-001: For copying
SP2-002-002: For making V
The first three digits are displayed in the
reduce/enlarge indicator. The actual
value is the displayed value x (–10) V.
Just after the main switch is turned on,
the initial setting voltage is displayed.
After one or more copies, the actual
applied voltage (including the process
control corrections) is displayed.
Adjusts the voltage applied to the drum
charge roller when making V
The adjustment factor set with this SP
SP
mode is added to the base voltage.
(10 V per step [Range: Base voltage
–160 V to Base voltage + 160 V])
1-67
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
Settings
0: OFF
1: 160 °C
2: 170 °C
0 ~ 32
Default = 16
0 ~ 32
Default = 16
0 - 32
Default = 16
(0 V) ‡
patterns
SP
0 - 32
patterns.
Default = 16
SP
(0 V) ‡
A207/A208/A211