Error Code
Code
Error Name
Contents
Disorder of communication
with the sub CPU
0002
Sub CPU Error
This occurs when the sub
CPU is not detected after
turning on the printer.
0004
Sub CPU SRAM error
Sub CPU SRAM error
An error occurs when
Sub CPU download
0005
downloading a program for
error
the sub CPU.
Sub CPU
An error occurs when
0006
Communication
communicating with the
Error
sub CPU.
Sub CPU command
An error occurs while
0007
error
sending a command.
Sub CPU
There is a problem with
communication
synchronizing serial
0008
error (serial
communication to the sub
synchronization)
CPU.
Network
Network I/F Initialize has not
0010
initialization error
been completed.
Limit Position Initialize in
Limit position
0101
the service mode has not
intialize error
been done.
The head lock sensor is ON
0102
Limit sensor error
when it should be OFF, or
vice versa.
Cause
The servo board does not work
correctly.
The sub CPU does not work
correctly.
There is a bad connection
between the main board and
the servo board.
SRAM is broken.
The servo board does not work
correctly.
The sub CPU does not work
correctly.
There is a bad connection
between the main board and
the servo board.
A noise on a signal
A noise on a signal while
sending a command.
The sub CPU was reset to
default.
Tried to communicate when
the sub CPU was reset to
default.
The servo board does not work
correctly.
The sub CPU does not work
correctly.
There is a bad connection
between the main board and
the servo board.
A noise on a signal while
sending a command.
The sub CPU was reset while
sending a command.
The servo board does not work
correctly.
The sub CPU does not work
correctly.
There is a bad connection
between the main board and
the servo board.
A noise on a signal.
Network I/F does not work
correctly.
Limit Position Initialize has not
been done.
Limit Position Initialize is ended
before it is completed.
The head lock sensor does not
work correctly or is broken.
4-3
Action
Check cable connection between the main board
and the servo board.
Check the other cable connections of the servo
board.
Servo board replacement
Main board replacement
Flexible cable replacement
Servo board replacement
Check cable connection between the main board
and the servo board.
Check the other cable connections of the servo
board.
Servo board replacement
Main board replacement
Flexible cable replacement
Check cable connection between the main board
and the servo board.
Check the other cable connections of the servo
board.
Servo board replacement
Main board replacement
Flexible cable replacement
Check cable connection between the main board
and the servo board.
Check the other cable connections of the servo
board.
Servo board replacement
Main board replacement
Flexible cable replacement
Check cable connection between the main board
and the servo board.
Check the other cable connections of the servo
board.
Servo board replacement
Main board replacement
Flexible cable replacement
Main board replacement
Complete Limit Position Initialize correctly.
Head lock sensor replacement
Check the mechanical backlash or loose with the scan
axis related parts.
4