Table Height Adjustment
8.
Tighten five fixing screws in the order shown in the figure .
2
4
9.
Measure the distance between the LM guide and table unit, and confirm that the difference between the reference value
and the value of the other points are within 0 .3 mm . If the difference is more than 0 .3 mm, go back to step 7 and repeat
the adjustment .
10.
Perform the following adjustments:
10-1.
Chapter 2 "Head Height Adjustment"
10-2.
Chapter 2 "UV Lamp Height Adjustment"
10-3.
Chapter 2 "Head Gap Sensor Position Adjustment"
10-4.
Chapter 2 "Print Area Adjustment"
10-5.
Chapter 2 "Head Alignment (HORIZONTAL only)"
11.
When all adjustments are finished, perform test print referring to the following procedure .
11-1.
Turn on the main power switch, and then turn on the sub power switch while pressing [] [] [] keys to enter the
service mode
MENU
SERVICE MENU
3
5
1
+
MENU
2-71
2
L EF 2-200