Board Replacement
8.
Unplug the connectors and disconnect the ribbon cable from the servo board and the signal junction board . Then pull
out the third board stay .
9.
Remove the main board and replace it with a new one .
10.
Change DIP switch of the new main board .
Bit 1
DIP SW
OFF
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
OFF
ON
ON
OFF
OFF