Circulation Pump Replacement
12.
Attach the motor .
13.
Attach the circulation pump plate .
14.
Attach the pump unit to the machine .
15.
Connect the ink tubes from the ink cartridge and the ink tubes from the print-head carriage to the pump .
C AUTION
• Insert the tubes as far as they will go .
• Refer to the figure and connect the ink tubes . Wrongly connected tube does not circulate the ink correctly .
• As indicated in the rear and top view, connect the tube from the print-head carriage to the right connector of the pump,
and connect the tube from the Y tube joint to the left connector of the pump .
Rear view
Print carriage
Ink cartridge
16.
Plug the connector of the motor .
17.
Turn on the main power switch . Then, turn on the sub power switch while pressing the [] [] [] keys to enter the
service mode .
18.
Select [SERVICE MENU] > [I/S MENU] > [PUMP CHECK] > [PUMP SUCTION] > [CIR-PUMP], and press the [ENTER] key . Visually
check that the pump works properly .