Beisler 1280-7 Operating Instructions Manual page 205

Table of Contents

Advertisement

Troubleshooting
Group
Number
Error
2114
Error
2152
Error
2156
Error
2214
Error
2252
Error
2256
Error
2314
Error
2352
Error
2356
Error
2914
Error
3100
Error
3101
Error
3102
Information
3103
Warning
3104
Error
3105
Error
3106
Information
3107
Information
3108
Error
3131
Operating Instructions 1280-7/1281-7 - 00.0 - 01/2023
Description
Stepper motor X Functional error
Stepper motor X Overcurrent
Stepper motor X Overtemperature
Stepper motor Y Functional error
Stepper motor Y Overcurrent
Stepper motor Y Overtemperature
Stepper motor Z Functional error
Stepper motor Z Overcurrent
Stepper motor Z Overtemperature
Stepper motor calculation error
AC-RDY timeout,
DC link voltage has not reached
the defined threshold.
High voltage error,
mains voltage > 290V for a long time.
nd
Low voltage error (2
threshold)
(mains voltage < 150V AC)
st
Low voltage warning (1
threshold)
(mains voltage < 180V AC)
Pedal is not in
position 0
U24V short circuit
U24V (I²T) overload
Foot pedal not connected
Speed limited due to insufficient
mains voltage
U60V short circuit
Corrective
• Update software
• Check the stepper motor
• Replace the control
• Update software
• Check the stepper motor
• Update software
• Check the stepper motor
• Update software
• Check the stepper motor
• Replace the control
• Update software
• Check the stepper motor
• Update software
• Check the stepper motor
• Update software
• Check the stepper motor
• Replace the control
• Update software
• Check the stepper motor
• Update software
• Check the stepper motor
• Update software
• Check mains voltage
• If mains voltage is OK, replace control unit.
• Check mains voltage
• Stabilize the mains voltage
• Check mains voltage
• Stabilize the mains voltage
• Check mains voltage
• Stabilize the mains voltage
• Take your foot off the pedal when switching
on the controller
• Check the pedal setting
• Disconnect 37-pin plug, if error 3105
persists, replace control unit.
• Test inputs/outputs for 24V short circuit
• One or more of the magnets defective
• Connect pedal to enable starts by foot pedal
and intermediate stops.
• Check mains voltage
• Update software
• One or several stepper motors defective
• Replace the control
203

Advertisement

Table of Contents
loading

This manual is also suitable for:

1281-7

Table of Contents