Beisler 1280-7 Operating Instructions Manual page 128

Table of Contents

Advertisement

Programming Commander Pro
Symbol/parameter
Submenu/setting
7.2.6
Start Mode
Value range: ON/OFF
Other setting options:
7.2.6.1
Start mode 1: Automatic sewing start by light
barrier
Fully automatic sewing start via light barrier recognition
Value range: ON/OFF
7.2.6.2
Start mode 2: Manual sewing start by foot pedal
Manual sewing start/Manual sewing via pedal, then activate the
automatic sewing start after xxxx cm.
Value range: ON/OFF
7.2.6.3
Start mode 3:
1.manual sewing start, 2.contour guide,
3.automatic sewing start by foot pedal.
Manual sewing start/Manual sewing via pedal, then press pedal to
activate automatic sewing start.
Value range: ON/OFF
7.2.6.6
Sewing length until automatic sewing start
Setting the seam length in cm until automatic change to automatic
sewing start.
Value range: 0-100 cm
126
Operating Instructions 1280-7/1281-7 - 00.0 - 01/2023