5.3.2

Tracking Configuration Sub-Menu

This menu gives access to all the parameters allowing to properly set-up the interface with the Ground
Station tracking system, mainly AGC and AM signals.
In operational mode, AGC is in Automatic mode in order to compensate the varying level of the input signal. In
this mode, the choice of Time Constant has to be made, generally based on the tracking system characteristics.
NEW FEATURE: A new technique has been implemented in the receiver to properly extract AM signal even
with a short AGC time constant which is necessary to track high rate fading. Hence, it is recommended to set
the time constant for AGC to 0.1 ms.
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
-
Date:
21/06/2021