Various LDPC codes can be selected, as per the IRIG106 recommendation. They will be activated when the SOQPSK-
LDPC mode will be selected on the Main Menu (cf 5.2.3 )
The Rate parameter allows the LDPC selection with
dedicated block size and rate. The output data rate will be
affected by the reverse of the Bandwidth Expansion factor
as described in IRIG 106-15 Appendix R – Table R-11
Bandwidth Expansion factor.
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
Date:
21/06/2021
Table 8: IRIG106-15 LDPC Bandwidth Expansion Factor
Safran Data Systems
-
.