Bits per Word
Frame Size
Data Polarity
SFID Position
Allowed Bit-Slip
Allowed Errors in Sync Word
Check to Lock threshold
Lock to Search threshold
For Frame Sync configuration detail, please refer to chapter 7.12
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
Date:
21/06/2021
It can take values from 4 to 64.
For values <=32 bits, it will take the information for the
Sync Word LSB.
For values >32, it will take the additional bits from the
Sync Word MSB
This parameter defines the numbers of bits composing
each word in the frame. It can take values from 4 to 16
This parameter determines the size in terms of Word of
a minor frame including sync word.
This parameter allows changing the data polarity of the
frame.
This parameter determines the position of the
SubFrame ID in the minor frame, starting after the
Sync Word
This parameter allows extending the sync word search
around its expected position in the minor frame. (0, +/-
1 bit, +/-2 bits, +/-3 bits)
This parameter sets the number of errors allowed in a
sync word. It can be useful in a noisy environment,
when error correction is present after the frame sync.
This value is allowed from 0 to 64.
This parameter sets the number of consecutive correct
sync word positions required to have the frame sync
locked. It can take values from 0 to 7.
This parameter sets the number of consecutive frames
without a correct sync word for the locked frame sync
to become unlocked. It can take values from 0 to 7