10
A
D
LARMS
ESCRIPTION
Code
0x00000001 Minor alarm ADP3
0x00000002 Major alarm ADP3
0x00000010 Minor alarm Tuner 1
0x00000020 Major alarm Tuner 1
0x00000040 Minor alarm Tuner 2
0x00000080 Major alarm Tuner 2
0x00000100 Minor alarm multiband 1
0x00000200 Major alarm multiband 1
0x10000000 Minor alarm system
0x20000000 Major alarm system
0x40000000 Minor alarm sum
0x80000000 Major alarm sum
Code
0x00000001 User 1 AM Delay
0x00000002 User 2 AM Delay
0x00000004 User 3 AM Delay
0x00000008 User 4 M Delay
0x00000010 User 5 AM Delay
0x00000020 User 6 AM Delay
0x00000100 Video 1 gain is 100%
0x00000200 Video 2 gain is 100%
0x00000400 Video 3 gain is 100%
0x00000800 Video 4 gain is 100%
0x00010000 Storage Telemetry TMU 1
0x00020000 Storage Telemetry TMU 2
0x00040000 Storage Telemetry TMU 3
0x00080000 Storage Telemetry TMU 1 Secondary
0x00100000 Storage Telemetry TMU 2 Secondary
0x00200000 Storage Telemetry TMU 3 Secondary
0x10000000 Equalizer filter IF not adequate
0x20000000 Equalizer filter IF not supported
0x40000000 Minor alarm sum
0x80000000 Major alarm sum
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
Alarm Sum
Alarm
System Alarm
Alarm
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
Date:
21/06/2021
Probable Origin
Probable Origin
The programmed AM delay cannot be reached, need
to increase the IF or AM filter width.
Video gain reached its maximum value. IF filter too
wide compare to FM modulation index or Carrier not
modulated.
File size greater than max
File creation error
File save error
Bit rate greater than max authorized
IF Filter too wide, reduce the IF filter width
Safran Data Systems
-
.