Dd-1494 Form Example - Safran RX-1 User Manual

Compact operational receiver
Hide thumbs Also See for RX-1:
Table of Contents

Advertisement

12
DD-1494 F
ORM EXAMPLE
CLASSIFICATION
UNCLASSIFIED
1. NOMENCLATURE, MANUFACTURER'S MODEL NO.
RX-1 S107714
3. RECEIVER INSTALLATION
Fixed or mobile, Remote control through Ethernet
link
5. TUNING RANGE
200MHz -5,250MHz
7. RF CHANNELING CAPABILITY
P : 200 MHz – 500 MHz
C-IF : 400 MHz – 1,150 MHz
LL :1429 MHz – 1545 MHz
UL : 1710 MHz – 1850 MHz
S : 2,180 MHz – 2,485 MHz
Low C: 4,400 MHz – 4,940 MHz
Mid-C: 5,090 MHz - 5,250 MHz
9. FREQUENCY TOLERANCE
+/- 1 PPM
10. IF SELECTIVITY
a. -3 dB
b. -20 dB
c. -45 dB
d. -60 dB
12. IF FREQUENCY
500 MHz
a. 1st
(Synthesizer: 1680MHz-1985MHz - Steps 1MHz)
70 MHz
b. 2nd
(Synthesizer: 430MHz +/- 0.5MHz, Steps 0.1 MHz)
c. 3rd
15. OSCILLATOR TUNED
a. ABOVE TUNED
FREQUENCY
b. BELOW TUNED
FREQUENCY
c. EITHER ABOVE OR
BELOW THE FREQUENCY
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
RECEIVER EQUIPMENT CHARACTERISTICS
1st
2nd
1st
2nd
X
X
2. MANUFACTURER'S NAME
Safran Data Systems S.A.
4. RECEIVER TYPE
Superheterodyne
6. METHOD OF TUNING
Synthesizer -
8. EMISSION DESIGNATOR(S)
3rd
11. RF SELECTIVITY (X and complete as applicable)
CALCULATED
a. -3 dB
b. -20 dB
c. -60 dB
d. Preselection Type
SAW Filter
13. MAXIMUM POST DETECTION FREQUENCY
14. MINIMUM POST DETECTION FREQUENCY
16. MAXIMUM BIT RATE
125kbpd
3rd
17. SENSITIVITY
a. SENSITIVITY
b. CRITERIA
c. NOISE FIG
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
-
Date:
21/06/2021
PAGE
Frequency step 100 kHz in RF / 1Hz NCO in digital
MEASURED
-110.0 dBm
8 dB
Safran Data Systems
.
3 of 5 Pages
Page 138