7.14

COFDM : Synchronization State machine

Training sequence
not detected
Training sequence detected
and Fine synch locked
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
Training sequence
detected
Training sequence
detected = CTL
Training sequence
not detected or Fine
synch unlocked
Training sequence not
detected or Fine
synch unlocked
Frame number = LTS
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
-
Date:
21/06/2021
Training sequence
not detected
Number of detected
TS < CTL
Training sequence not
detected or Fine synch
unlocked
Frame number < LTS
LTS: number of frame
before search depends on
fine synch parameters