The physical video outputs are used to send the video / baseband signals, but they could be used also as to send
the tape outputs (as described in 4.4.1 ). This usage is exclusive, and by default, the video / baseband signals
are sent.
Filter (Analog FM only) : Allow the selection of a filter at the output of the demodulator and before the Bit
Synchronizer. The following filters are available (12.5 kHz, 25 kHz, 50 kHz, 100 kHz, 250 kHz, 500 kHz,
750 kHz, 1 MHz, 1.5 MHz, 2 MHz, 3 MHz, 4 MHz, 5 MHz, 6 MHz, 8 MHz, 10 MHz, by-pass (20 MHz))
Polarity : Normal or inverted
De-Emphasis (Analog FM only) : Off, PAL or NTSC
Coupling : Output coupling AC or DC
Impedance : Output impedance (Low, 50 ohms, 75 Ohms)
Level : Output level peak to peak adjustment when in auto-level mode.
Auto-Level : This parameter allows to enable the auto-level mode, i.e. adjusting automatically the output
gain in order to get the expected Output Level (set-up with the parameter described above)
Figure 45: RX-1 Advanced Menu (Video Sub-Menu – Type Video)
© Safran Data Systems – IMP000074 e14r1
RX-1 Compact Operational Receiver
User's Manual
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D104047
Is.Rev
08
Previous Ref.:
-
Date:
21/06/2021
Safran Data Systems
.
Page 88