Name
Connected time
Unconnected time
Number of connections (in the
Output Tag Set Tab Page)
Number of connected origina-
tors (in the Output Tag Set
Tab Page)
Originator list (in the Output
Tag Set Tab Page), Target list
(in the Input Tag Set Tab
Page)
Originator name (in the
Output Tag Set Tab Page),
or Produced tag name (in
the Input Tag Set Tab
Page)
IP address (in the Output
Tag Set Tab Page), or Re-
mote IP address (in the
Input Tag Set Tab Page)
Connected time (in the
Output Tag Set Tab Page)
Unconnected time (in the
Output Tag Set Tab Page)
Destination IP address (in
the Output Tag Set Tab
Page)
O->T RPI (packet interval)
T->O Heartbeat transmis-
sion cycle (ms)
O->T Timeout
T->O Timeout
O -> T API (actual packet
interval)
T->O Actual heartbeat
transmission cycle (ms)
O->T Connection ID
T->O Connection ID
• Ethernet Information Tab Page
This tab page displays the communications status at the communications driver level of the built-in
Ethernet/IP port.
The error counter information can be used to confirm whether communications problems have oc-
curred.
Under the Tag Data Link, you can confirm characteristics such as the bandwidth usage (PPS).
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Gives the total connection duration in milliseconds.
Gives the total disconnection duration in milliseconds.
Gives the number of connections.
Gives the number of the connected originator devices.
Gives the detailed information of the connected originators.
Gives no information.
Gives the IP addresses allocated for the originators.
Gives the total duration of connection with the originator in milliseconds.
Gives the total duration of disconnection with the originator in milliseconds.
Gives the destination IP addresses. If the multi-cast connections are used,
its own multi-cast address is displayed.
Gives the RPI of connection from the originator to the target in milliseconds.
Gives the heartbeat transmission period of the connections from the target
to the originator in milliseconds.
Gives the timeout time for the connections from the originator to the target
in milliseconds.
Gives the timeout time for the connections from the target to the originator
in milliseconds.
Gives the RPI of connection from the originator to the target in milliseconds.
Gives the actual heartbeat transmission period of the connections from the
target to the originator in milliseconds.
Gives the connection identification for the connections from the originator to
the target in hexadecimal.
Gives the connection identification for the connections from the target to the
originator in hexadecimal.
Description