Omron NJ Series User Manual page 310

Machine automation controller, cpu unit built-in ethernet/ip port
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

8 CIP Message Communications
Service
Parameter name
code
05 hex
Reset
*1.
The value is 01 hex for a CPU Unit with unit version 1.09 or earlier.
Class ID
Specify 01 hex.
Instance ID
Specify 00 or 01 hex.
Attribute ID
The attribute ID specifies the information to read.
 Class Attribute ID
The class attribute ID specifies the attribute of the entire object.
Attribute ID
Parameter name
01 hex
Revision
02 hex
Max Instance
 Instance Attribute ID
The instance attribute ID specifies the attribute of the instance.
Attribute ID
Parameter name
01 hex
Vendor ID
02 hex
Device Type
03 hex
Product Code
8-48
Description
Resets the built-in EtherNet/IP port.
This parameter is used to reset the built-in EtherNet/IP port
when you change the IP address or other parameter settings
and want to apply them.
Input one of the following values for the ServiceDat input vari-
able to the CIPSend instruction to specify the reset method.
00 hex: Resets the built-in EtherNet/IP port.
*1
02 hex
: Clears the saved tag data link settings and resets
the built-in EtherNet/IP port.
Description
Revision of the object
The maximum instance num-
ber
Description
Vendor ID
Device type
Product code
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Read data
Attrib-
Data
ute
type
Read
UINT
0001 hex
Read
UINT
0001 hex
Read data
Attribute
Data
type
Read
UINT
002F hex
Read
UINT
000C hex
Read
UINT
Refer to (1) Product Codes
for Each Model, below.
Supported serv-
ices
Instan-
Classes
ces
Not sup-
Support-
ported
ed
Value
Value

Advertisement

Table of Contents
loading